Construction:
Fabricated from solid 304 stainless
steel with GRP / Polycarbonate head.
Approved Fuel Pump Hydraulics:
Large capacity combined gear pump and air
separator. ‘Super-accurate-meter’
with 0.08% increment adjustment. Both units
of world-renowned quality. (n/a to LPG).
Flow Rates:
Standard speed nominal 45-55 litres
per minute (LPM).
Mid Speed nominal 70 litres per minute
(LPM).
High speed nominal 90 litres per minute
(LPM).
Higher flow rates on request.
Lube oil nominal 5-10 litres per minute
(LPM).
Adblue nominal 15 litres per minute (LPM)
Displays:
1” illuminated LCD displays
with superb all-round viewing angle.
Retail cash computing display showing
price per litre, volume and cash for current
sale.
Commercial display showing volume only
informat
ion in litres (gallons display on request).
Display retained for 15 minutes in the
event of a mains power failure.
Electronics:
Powerful compact microprocessor
unit and power supply with built-in memory
and comprehensive error checking. Control
functions accessed either via hand-held
infra-red controller with security coded
operation or managers keyswitch.
|
Electrics:
All units are supplied wtih 0.55kW EExd motors, (n/a to dispensers). Three phase motors
required for high capacity models or available
on request.
Hoses / Nozzles:
Standard speed units fitted with ¾”
diameter 3.3m length hose and automatic
lightweight nozzle. High speed units fitted
with 1” diameter 3.5m black hose and
high flow nozzle. (n/a lube oil or LPG).
Totalisers:
Cash and volume totalisers displayed
at the pump on demand and accessed via the
hand-held infra-red controller, managers
keyswitch, or pump-controller / fuel management
system.
Price Setting:
Prices can be set either manually
at the pump via the hand-held infra-red
controller or remotely via the pump controller
/ point-of-sale system. (n/a to nonretail
models).
Volume Limits:
Standard speed units factory set
at 100 litres. High speed units set at 900
litres, lube oil set at 20 litres. Other
settings on request subject to local / national
regulations.
Calibration:
Weights & Measures setting enables
required 0.005 litre resolution for meter
set-up.
|